{"product_id":"antarctica-nitrogen-open-head-cryotherapy-chamber","title":"Antarctica Nitrogen Open Head Cryotherapy Chamber — Whole Body, Simple or Grand","description":"\u003cdiv class=\"tro-catalog-content tro-product-7622219595837\"\u003e\n\u003ch3 dir=\"ltr\"\u003eOverview\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThe Antarctica Nitrogen is a head-out whole body cryotherapy chamber and the coldest unit in the Antarctica range, operating between −120 °C and −170 °C (−184 °F to −274 °F).\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eCooling is by liquid nitrogen, distributed through the manufacturer's Platinum Jet system, which is designed to spread the cold evenly through the cabin rather than concentrating it at the point of entry. The chamber is open at the top: the client stands with their head and airway above the rim, in ambient room air, throughout the session, so no respiratory equipment is worn.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eFor the temperatures it reaches, the electrical demand is unusually modest — up to 1.5 kW on a standard 110V\/60Hz or 220V\/50Hz supply, roughly a 20-amp line. No three-phase service and no electrical upgrade are required. The cooling energy comes from the nitrogen, not the grid, which is the trade-off this architecture makes: lower electrical infrastructure in exchange for a nitrogen supply contract and 3–5 kg of consumption per session or precooling cycle.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eOperation runs from a 10.1\" commercial touchscreen with preset programs and manual control. Sessions typically run one to three minutes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 dir=\"ltr\"\u003eSimple and Grand\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eBoth configurations share the same chamber, cooling system, dimensions and electrical requirements. The \u003cstrong\u003eGrand\u003c\/strong\u003e adds two client-facing instruments:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eA \u003cstrong\u003ethermal scope appliance\u003c\/strong\u003e for thermal imaging and evaluation of blood circulation\u003c\/li\u003e\n\u003cli\u003eA \u003cstrong\u003esensor monitoring the client's heart rate and blood oxygen level\u003c\/strong\u003e during the session\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003eThe \u003cstrong\u003eSimple\u003c\/strong\u003e is the chamber without those instruments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 dir=\"ltr\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eCryonick Wellness Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAntarctica Nitrogen — Simple \/ Grand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eWhole body cryotherapy chamber, head-out open design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eLiquid nitrogen, Platinum Jet distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−120 °C to −170 °C (−184 °F to −274 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e1 person\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSession duration\u003c\/td\u003e\n\u003ctd\u003eTypically 1–3 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 3–5 kg per session or precooling cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e1870 mm (74\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e1170 mm (46\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e2192 mm (86\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e450 kg (990 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight, crated\u003c\/td\u003e\n\u003ctd\u003e600 kg (1,322 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e110V\/60Hz or 220V\/50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy consumption\u003c\/td\u003e\n\u003ctd\u003eUp to 1.5 kW (approx. 20A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControls\u003c\/td\u003e\n\u003ctd\u003e10.1\" commercial touchscreen, preset and manual modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrand configuration adds\u003c\/td\u003e\n\u003ctd\u003eThermal scope for thermal imaging and circulation evaluation; client heart rate and blood oxygen sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRespiratory protection\u003c\/td\u003e\n\u003ctd\u003eNot required — the client's head remains above the chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eChamber unit, nitrogen cooling system, touchscreen controller, installation kit, operator manual and documentation, protective shipping crate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch3 dir=\"ltr\"\u003eFeatures\u003c\/h3\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eHead-out design — the client's head and airway remain in ambient room air throughout\u003c\/li\u003e\n\u003cli\u003eOperating range to −170 °C, the coldest chamber in the Antarctica range\u003c\/li\u003e\n\u003cli\u003ePlatinum Jet system for even distribution of cold through the cabin\u003c\/li\u003e\n\u003cli\u003eNo three-phase power required — 110V or 220V, up to 1.5 kW on approximately a 20A line\u003c\/li\u003e\n\u003cli\u003e10.1\" commercial touchscreen with preset and manual session control\u003c\/li\u003e\n\u003cli\u003e1–3 minute sessions\u003c\/li\u003e\n\u003cli\u003eGrand configuration adds thermal imaging with circulation evaluation and client biometric monitoring\u003c\/li\u003e\n\u003cli\u003eNitrogen consumption of approximately 3–5 kg per session\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3 dir=\"ltr\"\u003eBefore You Buy\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eProtective clothing is worn for every session\u003c\/strong\u003e — socks, gloves and undergarments. In a head-out chamber the extremities sit in the coldest part of the cabin, and this is not optional equipment.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003ePlan the nitrogen supply.\u003c\/strong\u003e Budget 3–5 kg per session or precooling cycle, and arrange dewar storage, securing, changeover and delivery access before the machine arrives.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eRoom ventilation and oxygen monitoring are the operator's responsibility.\u003c\/strong\u003e Nitrogen displaces oxygen, and the chamber's own controls govern the cabin, not the room it stands in. Confirm with the manufacturer and your local authority what room air-change rate and ambient oxygen monitoring your installation requires. Note that the Grand's oxygen sensor reads the client's blood oxygen — it is not an ambient room oxygen monitor.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSessions are attended.\u003c\/strong\u003e This chamber is designed for operator-supervised use.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eConfirm warranty terms at order.\u003c\/strong\u003e Vacuactivus offers extended coverage on other equipment in its range only within a short window after purchase, so settle the warranty question before you place the order rather than after delivery.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eAccess and installation.\u003c\/strong\u003e 600 kg crated and 2192 mm tall — check doorway, lift and floor loading on the delivery route.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"The Recovery Outlet","offers":[{"title":"Simple","offer_id":49390869971179,"sku":"sku-42312849326141","price":28500.0,"currency_code":"USD","in_stock":true},{"title":"Grand","offer_id":49390870003947,"sku":"sku-42312849358909","price":29950.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0846\/3007\/7675\/files\/Antaractica_Open_Head_Nitrogen_d68196a7-01ec-457b-b7a6-f35fe654ea53.png?v=1789083765","url":"https:\/\/thrivesector.com\/products\/antarctica-nitrogen-open-head-cryotherapy-chamber","provider":"Thrive Sector","version":"1.0","type":"link"}