{"product_id":"cryo-innovations-xr-cryo-chamber","title":"Vacuactivus Antarctica Electric Cryotherapy Chamber — Nitrogen-Free, Head-Out, Simple or Grand","description":"\u003cdiv class=\"tro-catalog-content tro-product-7727336063037\"\u003e\n\u003cp dir=\"ltr\"\u003eThe XR is a whole body cryotherapy chamber from Cryo Innovations, cooled by liquid nitrogen and built for commercial operation in chiropractic, physical therapy, gym, sports team, salon, spa and event settings.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eWhat separates it from most of the category is the compliance work behind it. The control panel is \u003cstrong\u003eUL Listed under file number E474341\u003c\/strong\u003e. The nitrogen system is built to \u003cstrong\u003eCGA G-4.1\u003c\/strong\u003e for oxygen-service cleanliness, welded to \u003cstrong\u003eASME Boiler and Pressure Vessel Code Section IX\u003c\/strong\u003e, and plumbed in \u003cstrong\u003eASTM B 819\u003c\/strong\u003e seamless copper — the same tubing standard used for medical gas. Assembly follows \u003cstrong\u003eInternational Plumbing Code Chapter 13\u003c\/strong\u003e and \u003cstrong\u003eNFPA 99\u003c\/strong\u003e, the Health Care Facilities Code. Vessels are pressure tested to 110% and 150% of maximum allowable working pressure. For an operator who has to satisfy a landlord, an insurer or a local authority before switching the machine on, that paperwork is the product.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe cabin is 316 stainless steel, chosen for corrosion resistance in an environment that cycles between deep cold and room humidity several times an hour. Usable height accommodates clients up to 7'2\", weight capacity is 1,000 lb, and the exterior footprint is 44\" × 34\" — small enough for rooms that won't take a full-size chamber. High-output LED lighting runs inside and outside the cabin.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eInstallation is deliberately undemanding on the building: the chamber runs from a standard 110V outlet, with no three-phase service and no electrical upgrade. What it does need is Wi-Fi and a liquid nitrogen supply, consuming roughly 2–3 litres per session.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eMonitoring and access control are where the XR is most unusual. Thermal imaging detects whether the client's head is present and reports real-time skin temperature. On-board sensors read blood oxygen, pulse, body temperature and client diagnostics through the session. Entry requires \u003cstrong\u003edual fingerprint authorization\u003c\/strong\u003e — both the operator and the client must approve — so the chamber cannot be started by an unattended client or an unauthorized one.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eSafety systems act on the nitrogen supply directly. An emergency stop and shut-off valve halt nitrogen flow; a door proximity sensor closes the valves whenever the door opens; and the system shuts down instantly if any safety sensor is triggered.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThere is no dry-out time between sessions, so appointments can run back to back. A built-in point-of-sale system is integrated into the chamber, and Wi-Fi connectivity supports live diagnostics and software updates. Operators running more than one chamber can manage all of them, and all client data, from the same system.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eRobes, booties and gloves are included. Cryo Innovations covers the XR with a three-year warranty, with extended coverage available.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 dir=\"ltr\"\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eCryo Innovations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eXR (Thermal Edition)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eWhole body cryotherapy chamber, enclosed, door access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eLiquid nitrogen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen consumption\u003c\/td\u003e\n\u003ctd\u003e2–3 litres per session\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e1 person\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsable height\u003c\/td\u003e\n\u003ctd\u003eUp to 7'-2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight capacity\u003c\/td\u003e\n\u003ctd\u003e1,000 lb (453 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior footprint\u003c\/td\u003e\n\u003ctd\u003e44\" × 34\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003e316 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eStandard 110V outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlso required\u003c\/td\u003e\n\u003ctd\u003eWi-Fi, liquid nitrogen supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLighting\u003c\/td\u003e\n\u003ctd\u003eHigh-output LED, cabin interior and exterior\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal imaging\u003c\/td\u003e\n\u003ctd\u003eHead-presence detection and real-time skin temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-board monitoring\u003c\/td\u003e\n\u003ctd\u003eBlood oxygen, pulse, body temperature, client diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccess control\u003c\/td\u003e\n\u003ctd\u003eDual fingerprint authorization — operator and client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety systems\u003c\/td\u003e\n\u003ctd\u003eEmergency stop and nitrogen shut-off valve; door proximity sensor closes valves; instantaneous shutdown on any triggered safety sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBetween sessions\u003c\/td\u003e\n\u003ctd\u003eNo dry-out time required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoint of sale\u003c\/td\u003e\n\u003ctd\u003eBuilt in; multi-chamber and client-data management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eWi-Fi — live diagnostics and software updates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl panel\u003c\/td\u003e\n\u003ctd\u003eUL Listed Industrial Control Panel, UL File No. E474341\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eCGA G-4.1 · ASME BPVC Section IX · ASTM B 819 · IPC Chapter 13 · NFPA 99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure testing\u003c\/td\u003e\n\u003ctd\u003e110% and 150% MAWP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eChamber, robes, booties, gloves, integrated monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3 years; extended coverage available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch3 dir=\"ltr\"\u003eFeatures\u003c\/h3\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eLiquid nitrogen whole body cryotherapy, 2–3 litres per session\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUL Listed industrial control panel, UL File No. E474341\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eBuilt to CGA G-4.1, ASME BPVC Section IX and ASTM B 819; assembled to IPC Chapter 13 and NFPA 99\u003c\/li\u003e\n\u003cli\u003ePressure tested to 110% and 150% MAWP\u003c\/li\u003e\n\u003cli\u003eRuns from a standard 110V outlet — no three-phase service, no electrical upgrade\u003c\/li\u003e\n\u003cli\u003eCompact 44\" × 34\" footprint; usable height to 7'-2\"; 1,000 lb capacity\u003c\/li\u003e\n\u003cli\u003e316 stainless steel cabin with high-output interior and exterior LED lighting\u003c\/li\u003e\n\u003cli\u003eThermal imaging for head presence and real-time skin temperature\u003c\/li\u003e\n\u003cli\u003eOn-board blood oxygen, pulse, body temperature and diagnostics\u003c\/li\u003e\n\u003cli\u003eDual fingerprint authorization — operator and client\u003c\/li\u003e\n\u003cli\u003eEmergency stop, nitrogen shut-off valve, door proximity shutoff, instantaneous sensor shutdown\u003c\/li\u003e\n\u003cli\u003eNo dry-out time between sessions\u003c\/li\u003e\n\u003cli\u003eBuilt-in POS with multi-chamber and client-data management\u003c\/li\u003e\n\u003cli\u003eWi-Fi live diagnostics and software updates\u003c\/li\u003e\n\u003cli\u003eRobes, booties and gloves included\u003c\/li\u003e\n\u003cli\u003e3-year warranty, extended coverage available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3 dir=\"ltr\"\u003eRequired disclosure\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eThe Pulse Oxygen Sensor and the Thermal Imaging Camera are not for medical purposes and are intended for information only.\u003c\/strong\u003e (Manufacturer's statement.)\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eKeep that with the monitoring feature wherever it appears — listing, comparison table, spec sheet. Whole body cryotherapy devices are not FDA-cleared to treat any medical condition, and the FDA has published consumer cautions about the practice. Any copy anywhere on your site that implies treatment of a condition creates a Merchant Center problem and an FTC substantiation problem at the same time.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 dir=\"ltr\"\u003eSite requirements the buyer needs to plan for\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis is a liquid nitrogen system, and nitrogen displaces oxygen. The XR's own safety systems govern the chamber; the \u003cstrong\u003eroom\u003c\/strong\u003e is the operator's responsibility. Before quoting an installation, confirm with Cryo Innovations and the local authority:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoom ventilation and oxygen monitoring.\u003c\/strong\u003e NFPA 99 and CGA guidance address nitrogen in occupied spaces. Ask specifically whether a room oxygen monitor is supplied, recommended or required — the XR's on-board sensor reads the \u003cem\u003eclient's\u003c\/em\u003e blood oxygen, not ambient air.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDewar siting, securing and changeover\u003c\/strong\u003e, and the delivery access that implies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperator training and supervision requirements.\u003c\/strong\u003e Dual fingerprint authorization is designed around an attended session; confirm the chamber is not intended for unattended use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"The Recovery Outlet","offers":[{"title":"Default Title","offer_id":49390862532843,"sku":"sku-42666932240445","price":35000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0846\/3007\/7675\/files\/XRstandalone_png.webp?v=1789083525","url":"https:\/\/thrivesector.com\/products\/cryo-innovations-xr-cryo-chamber","provider":"Thrive Sector","version":"1.0","type":"link"}