Antarctica Nitrogen Open Head Cryotherapy Chamber — Whole Body, Simple or Grand
Antarctica Nitrogen Open Head Cryotherapy Chamber — Whole Body, Simple or Grand
Couldn't load pickup availability
Share

Overview
The Antarctica Nitrogen is a head-out whole body cryotherapy chamber and the coldest unit in the Antarctica range, operating between −120 °C and −170 °C (−184 °F to −274 °F).
Cooling is by liquid nitrogen, distributed through the manufacturer's Platinum Jet system, which is designed to spread the cold evenly through the cabin rather than concentrating it at the point of entry. The chamber is open at the top: the client stands with their head and airway above the rim, in ambient room air, throughout the session, so no respiratory equipment is worn.
For the temperatures it reaches, the electrical demand is unusually modest — up to 1.5 kW on a standard 110V/60Hz or 220V/50Hz supply, roughly a 20-amp line. No three-phase service and no electrical upgrade are required. The cooling energy comes from the nitrogen, not the grid, which is the trade-off this architecture makes: lower electrical infrastructure in exchange for a nitrogen supply contract and 3–5 kg of consumption per session or precooling cycle.
Operation runs from a 10.1" commercial touchscreen with preset programs and manual control. Sessions typically run one to three minutes.
Simple and Grand
Both configurations share the same chamber, cooling system, dimensions and electrical requirements. The Grand adds two client-facing instruments:
- A thermal scope appliance for thermal imaging and evaluation of blood circulation
- A sensor monitoring the client's heart rate and blood oxygen level during the session
The Simple is the chamber without those instruments.
Key Specifications
| Brand | Cryonick Wellness Technology |
| Model | Antarctica Nitrogen — Simple / Grand |
| Type | Whole body cryotherapy chamber, head-out open design |
| Cooling | Liquid nitrogen, Platinum Jet distribution |
| Operating temperature | −120 °C to −170 °C (−184 °F to −274 °F) |
| Capacity | 1 person |
| Session duration | Typically 1–3 minutes |
| Nitrogen consumption | Approx. 3–5 kg per session or precooling cycle |
| Length | 1870 mm (74") |
| Width | 1170 mm (46") |
| Height | 2192 mm (86") |
| Net weight | 450 kg (990 lb) |
| Shipping weight, crated | 600 kg (1,322 lb) |
| Power supply | 110V/60Hz or 220V/50Hz |
| Energy consumption | Up to 1.5 kW (approx. 20A) |
| Controls | 10.1" commercial touchscreen, preset and manual modes |
| Grand configuration adds | Thermal scope for thermal imaging and circulation evaluation; client heart rate and blood oxygen sensor |
| Respiratory protection | Not required — the client's head remains above the chamber |
| Included | Chamber unit, nitrogen cooling system, touchscreen controller, installation kit, operator manual and documentation, protective shipping crate |
Features
- Head-out design — the client's head and airway remain in ambient room air throughout
- Operating range to −170 °C, the coldest chamber in the Antarctica range
- Platinum Jet system for even distribution of cold through the cabin
- No three-phase power required — 110V or 220V, up to 1.5 kW on approximately a 20A line
- 10.1" commercial touchscreen with preset and manual session control
- 1–3 minute sessions
- Grand configuration adds thermal imaging with circulation evaluation and client biometric monitoring
- Nitrogen consumption of approximately 3–5 kg per session
Before You Buy
Protective clothing is worn for every session — socks, gloves and undergarments. In a head-out chamber the extremities sit in the coldest part of the cabin, and this is not optional equipment.
Plan the nitrogen supply. Budget 3–5 kg per session or precooling cycle, and arrange dewar storage, securing, changeover and delivery access before the machine arrives.
Room ventilation and oxygen monitoring are the operator's responsibility. Nitrogen displaces oxygen, and the chamber's own controls govern the cabin, not the room it stands in. Confirm with the manufacturer and your local authority what room air-change rate and ambient oxygen monitoring your installation requires. Note that the Grand's oxygen sensor reads the client's blood oxygen — it is not an ambient room oxygen monitor.
Sessions are attended. This chamber is designed for operator-supervised use.
Confirm warranty terms at order. Vacuactivus offers extended coverage on other equipment in its range only within a short window after purchase, so settle the warranty question before you place the order rather than after delivery.
Access and installation. 600 kg crated and 2192 mm tall — check doorway, lift and floor loading on the delivery route.